0

  • English
  • Greek for Joomla! 1.0.x
thumb_header_short
group member of
logo_galenica
ISO certified by
thumb_LOGO
 
 
Flash Automated Systems Εκτύπωση
Image

Isolera
Flash Purification System

Intelligent features enable better separations in less
time with fewer resources.
High performance flash chromatography at its best.

 

 

Isolera Flash Purification System
Isolera™, a new more compact flash purification system with intelligent features, enables chemists to easily achieve better separations. The advanced TLC-to-gradient feature automatically creates elution gradients and suggests cartridge and sample size. Collect fractions using two wavelengths, adjust the flow rate from 1 to 200 mL/min as needed and use up to four solvents in a single gradient, for maximum purity and yield.

Isolera is available in a single cartridge base model, the Isolera One, and a 4-cartridge configuration, the Isolera Four, which is ideal for multi-user or high-throughput laboratories.

Faster Flow Rates – increase productivity and save valuable time

With a flow range of 1 to 200 mL/min, Isolera dramatically shortens purification run-times. For example, a 10.5 g sample was purified at 200 mL/min on a 340 g Biotage SNAP cartridge in less than 19 minutes, see figure 1. If this same separation had been performed using a typical flash system with a 100 mL/min flow rate limitation, the purification would have taken twice as long.

Isolera performance figures - Biotage Isolera_Figure1_340_KP-Sil.jpg

Figure 1.
The value of fast flow rates can be seen in the 10.5 gram purification at 200 mL/min using a SNAP 340g KP-SIL cartridge on an Isolera One. The total run time is 18.8 minutes.


Collect on 2 separate wavelengths – Recover more compounds


Collect eluting compounds that don’t absorb at the primary wavelength using the variable wavelength diode array detector option. Instead of fractionating on a single wavelength while monitoring a second, Isolera can fractionate simultaneous on two unique user-defined wavelengths. This capability enables chemists to recover more of the compounds and get cleaner fractions, as highlighted in figure 2.

Isolera performance figures - Biotage Isolera_Figure2_wavelengths.jpg

Figure 2.
Fractionation using two wavelengths ensures collection of UV absorbing compounds at both wavelengths without sacrificing valuable fraction collection capacity in a “collect all” mode.

Additional features:

• Largest integrated fraction capacity
• Quatro-binary Gradient – Use up to four solvents in a single gradient
• Isocratic co-solvent – increase compound solubility and recovery
• Default Methods – simplify method creation
• On-the-fly editing – modify purification runs in progress
• SNAP cartridges – increase loading capacity and improve compound separations.
• Add an auxiliary detector – Use other detectors
• An assortment of SNAP cartridges is included with the Isolera system
• Connect an external auxiliary detector (refractive index or ELSD)

Isolera fully integrated with Biotage SNAP Cartridges-250px

click for more information

or contact us 

 

 
< Προηγ.   Επόμ. >
Free Joomla Templates